<i>Thresholds Scan<br />185 M3R4 chambers passed the tests</i></font>

Thresholds Scan
185 M3R4 chambers passed the tests


Tables below present:
- Thr_Max(r.u.), Thresholds in register units at Maximum of noise rate;
- N_Max, Noise rate at Thr_Max in counts/sec;
- D_100 = Thr_100(r.u.) - Thr_Max(r.u.) where Thr_100(r.u.) is the threshold in register units at noise rate = 100/s.
The following expression relates the real threshold (measured from the base-line of physical signals) with the thresholds determined by the register units:
Thr(fC)*S(r.u./fC) = Thr(r.u.) - Thr_Max(r.u.)+ OFFSet(r.u.).
Here, OFFSet=17 register units;
S=3.40 r.u./fC is the charge sensitivity corresponding to S=8mV/fC taken for M3R4 chambers;
(Note, that 1 register unit = 2.35 mV)

FEB-1. Mean values. FEB-2. Mean values. FEB-3. Mean values.
Chamber Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Test Date Plots Comments
105 83 561584 13 77 464188 12 79 406660 12 13-JUN-07
<font color="DarkRed" size="5"><i><b>Thr_Max in register units for M3R4-105</b></i><br /></font>

Thr_Max in register units for M3R4-105

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 76 82 78 86 86 87 87 92 75 89 78 85 81 86 85 80
FEB-2 77 78 70 77 84 73 75 71 79 74 79 78 75 77 83 83
FEB-3 81 77 83 75 82 89 74 75 76 78 77 81 84 77 81 76
<font color="DarkRed" size="5"><i><b>Noise rate at Thr_Max [counts/sec] for M3R4-105</b></i><br /></font>

Noise rate at Thr_Max [counts/sec] for M3R4-105

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 653581 620629 663063 646093 476869 475233 527131 570076 497077 376705 532746 335971 554211 440861 723747 891351
FEB-2 333127 493148 390336 560954 328653 483774 333746 391146 314522 486551 425441 474317 602194 565141 557434 686517
FEB-3 365738 487384 454004 274582 388809 619843 349427 219902 523401 285232 432895 250246 397884 448054 542522 466631
<font color="DarkRed" size="5"><i><b><FONT FACE="Symbol">D_100 </FONT> - in register units for M3R4-105</b></i><br /></font>

D_100 - in register units for M3R4-105

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 15 14 14 12 13 12 14 12 13 12 14 12 12 12 15 14
FEB-2 11 13 12 12 11 12 10 12 11 13 11 13 11 14 12 12
FEB-3 12 12 11 10 12 12 11 11 13 11 11 11 12 11 14 11
<font color="DarkRed" size="5"><i><b>Noise counts vs Thresholds. M3R4-105</b></i></font>

Noise counts vs Thresholds. M3R4-105


Noise rates vs Thresholds for FEB-1 Noise rates vs Thresholds for FEB-2 Noise rates vs Thresholds for FEB-3
<font color="DarkRed" size="5"><i><b>PLOTS of Thresholds Scan Results. M3R4-105</b></i></font>

PLOTS of Thresholds Scan Results. M3R4-105

Scan results for FEB-1 (left plots), for FEB-2 (middle plots), for FEB-3 (right plots).
Thr_Max vs channel number (upper plot)
N_Max vs channel number (middle plot)
D_100 vs channel number (lower plot)

For comments, contact: Petr.Neustroev@cern.ch