<i>Thresholds Scan<br />185 M3R4 chambers passed the tests</i></font>

Thresholds Scan
185 M3R4 chambers passed the tests


Tables below present:
- Thr_Max(r.u.), Thresholds in register units at Maximum of noise rate;
- N_Max, Noise rate at Thr_Max in counts/sec;
- D_100 = Thr_100(r.u.) - Thr_Max(r.u.) where Thr_100(r.u.) is the threshold in register units at noise rate = 100/s.
The following expression relates the real threshold (measured from the base-line of physical signals) with the thresholds determined by the register units:
Thr(fC)*S(r.u./fC) = Thr(r.u.) - Thr_Max(r.u.)+ OFFSet(r.u.).
Here, OFFSet=17 register units;
S=3.40 r.u./fC is the charge sensitivity corresponding to S=8mV/fC taken for M3R4 chambers;
(Note, that 1 register unit = 2.35 mV)

FEB-1. Mean values. FEB-2. Mean values. FEB-3. Mean values.
Chamber Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Test Date Plots Comments
111 75 397288 11 79 455947 12 76 360442 11 03-JUL-07
<font color="DarkRed" size="5"><i><b>Thr_Max in register units for M3R4-111</b></i><br /></font>

Thr_Max in register units for M3R4-111

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 70 82 70 76 67 79 79 78 76 74 77 73 73 75 81 73
FEB-2 78 73 75 88 75 82 70 77 77 88 71 83 79 88 82 80
FEB-3 74 78 80 72 68 82 73 81 77 83 68 79 72 81 67 74
<font color="DarkRed" size="5"><i><b>Noise rate at Thr_Max [counts/sec] for M3R4-111</b></i><br /></font>

Noise rate at Thr_Max [counts/sec] for M3R4-111

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 258690 604389 384623 363653 234511 609237 556363 302936 527903 239281 385197 249983 290592 518728 443482 387038
FEB-2 520014 560148 441596 773158 538551 373634 429071 339471 308456 301299 360029 354902 367633 380868 627896 618424
FEB-3 345593 466471 623678 424390 273310 236012 255728 375095 279765 303808 268163 266417 356543 444027 468582 379488
<font color="DarkRed" size="5"><i><b><FONT FACE="Symbol">D_100 </FONT> - in register units for M3R4-111</b></i><br /></font>

D_100 - in register units for M3R4-111

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 10 13 11 12 9 12 10 11 13 10 12 10 10 11 13 13
FEB-2 13 13 13 14 13 12 13 12 12 11 11 11 12 11 13 13
FEB-3 12 13 11 11 11 10 11 11 11 10 9 10 11 11 13 11
<font color="DarkRed" size="5"><i><b>Noise counts vs Thresholds. M3R4-111</b></i></font>

Noise counts vs Thresholds. M3R4-111


Noise rates vs Thresholds for FEB-1 Noise rates vs Thresholds for FEB-2 Noise rates vs Thresholds for FEB-3
<font color="DarkRed" size="5"><i><b>PLOTS of Thresholds Scan Results. M3R4-111</b></i></font>

PLOTS of Thresholds Scan Results. M3R4-111

Scan results for FEB-1 (left plots), for FEB-2 (middle plots), for FEB-3 (right plots).
Thr_Max vs channel number (upper plot)
N_Max vs channel number (middle plot)
D_100 vs channel number (lower plot)

For comments, contact: Petr.Neustroev@cern.ch