<i>Thresholds Scan<br />185 M3R4 chambers passed the tests</i></font>

Thresholds Scan
185 M3R4 chambers passed the tests


Tables below present:
- Thr_Max(r.u.), Thresholds in register units at Maximum of noise rate;
- N_Max, Noise rate at Thr_Max in counts/sec;
- D_100 = Thr_100(r.u.) - Thr_Max(r.u.) where Thr_100(r.u.) is the threshold in register units at noise rate = 100/s.
The following expression relates the real threshold (measured from the base-line of physical signals) with the thresholds determined by the register units:
Thr(fC)*S(r.u./fC) = Thr(r.u.) - Thr_Max(r.u.)+ OFFSet(r.u.).
Here, OFFSet=17 register units;
S=3.40 r.u./fC is the charge sensitivity corresponding to S=8mV/fC taken for M3R4 chambers;
(Note, that 1 register unit = 2.35 mV)

FEB-1. Mean values. FEB-2. Mean values. FEB-3. Mean values.
Chamber Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Test Date Plots Comments
51 79 510587 12 78 489767 12 81 424431 13 04-JUL-07
<font color="DarkRed" size="5"><i><b>Thr_Max in register units for M3R4-51</b></i><br /></font>

Thr_Max in register units for M3R4-51

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 79 81 81 84 80 81 79 83 77 79 74 80 80 70 75 78
FEB-2 79 71 81 76 79 74 83 70 76 73 85 67 86 80 82 80
FEB-3 78 82 75 86 76 88 71 88 79 91 78 82 71 84 82 84
<font color="DarkRed" size="5"><i><b>Noise rate at Thr_Max [counts/sec] for M3R4-51</b></i><br /></font>

Noise rate at Thr_Max [counts/sec] for M3R4-51

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 506788 540736 961063 453624 474087 347840 481770 411586 416819 273034 496177 319290 661453 399075 713550 712494
FEB-2 688846 509225 733148 450391 394774 412680 356923 389175 337715 481073 639833 305984 437331 417650 545122 736397
FEB-3 458696 471875 484904 403494 401552 385647 350879 360767 323193 380826 412486 218798 341365 483459 543293 769662
<font color="DarkRed" size="5"><i><b><FONT FACE="Symbol">D_100 </FONT> - in register units for M3R4-51</b></i><br /></font>

D_100 - in register units for M3R4-51

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 13 12 15 12 13 11 12 10 11 10 12 12 14 11 14 11
FEB-2 14 13 12 13 11 12 11 12 12 13 13 11 12 12 13 12
FEB-3 14 14 12 14 13 13 12 11 12 12 13 9 12 14 13 15
<font color="DarkRed" size="5"><i><b>Noise counts vs Thresholds. M3R4-51</b></i></font>

Noise counts vs Thresholds. M3R4-51


Noise rates vs Thresholds for FEB-1 Noise rates vs Thresholds for FEB-2 Noise rates vs Thresholds for FEB-3
<font color="DarkRed" size="5"><i><b>PLOTS of Thresholds Scan Results. M3R4-51</b></i></font>

PLOTS of Thresholds Scan Results. M3R4-51

Scan results for FEB-1 (left plots), for FEB-2 (middle plots), for FEB-3 (right plots).
Thr_Max vs channel number (upper plot)
N_Max vs channel number (middle plot)
D_100 vs channel number (lower plot)

For comments, contact: Petr.Neustroev@cern.ch