<i>Thresholds Scan<br />185 M3R4 chambers passed the tests</i></font>

Thresholds Scan
185 M3R4 chambers passed the tests


Tables below present:
- Thr_Max(r.u.), Thresholds in register units at Maximum of noise rate;
- N_Max, Noise rate at Thr_Max in counts/sec;
- D_100 = Thr_100(r.u.) - Thr_Max(r.u.) where Thr_100(r.u.) is the threshold in register units at noise rate = 100/s.
The following expression relates the real threshold (measured from the base-line of physical signals) with the thresholds determined by the register units:
Thr(fC)*S(r.u./fC) = Thr(r.u.) - Thr_Max(r.u.)+ OFFSet(r.u.).
Here, OFFSet=17 register units;
S=3.40 r.u./fC is the charge sensitivity corresponding to S=8mV/fC taken for M3R4 chambers;
(Note, that 1 register unit = 2.35 mV)

FEB-1. Mean values. FEB-2. Mean values. FEB-3. Mean values.
Chamber Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Test Date Plots Comments
57 82 551024 14 77 435698 11 74 538173 13 19-JUN-07
<font color="DarkRed" size="5"><i><b>Thr_Max in register units for M3R4-57</b></i><br /></font>

Thr_Max in register units for M3R4-57

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 79 92 79 85 84 84 75 81 80 83 83 77 80 82 83 79
FEB-2 84 68 79 72 79 76 83 70 78 74 83 69 85 69 85 70
FEB-3 69 82 71 79 72 69 75 72 72 75 72 72 72 74 81 71
<font color="DarkRed" size="5"><i><b>Noise rate at Thr_Max [counts/sec] for M3R4-57</b></i><br /></font>

Noise rate at Thr_Max [counts/sec] for M3R4-57

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 472299 577315 695655 573482 299524 421815 473592 399068 451999 457201 792154 590101 662788 606385 673953 669050
FEB-2 613521 478997 557951 397013 435141 308149 425649 363262 452329 268134 372259 285446 427242 426410 628714 530953
FEB-3 543305 628651 410309 591598 530806 438329 530727 379676 302032 793446 412070 485282 516306 567541 719279 761406
<font color="DarkRed" size="5"><i><b><FONT FACE="Symbol">D_100 </FONT> - in register units for M3R4-57</b></i><br /></font>

D_100 - in register units for M3R4-57

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 15 14 15 15 12 13 13 14 13 14 16 16 14 13 15 15
FEB-2 12 12 12 10 12 11 12 11 13 11 11 10 13 11 12 10
FEB-3 14 14 13 14 14 12 12 12 11 12 13 13 15 14 13 14
<font color="DarkRed" size="5"><i><b>Noise counts vs Thresholds. M3R4-57</b></i></font>

Noise counts vs Thresholds. M3R4-57


Noise rates vs Thresholds for FEB-1 Noise rates vs Thresholds for FEB-2 Noise rates vs Thresholds for FEB-3
<font color="DarkRed" size="5"><i><b>PLOTS of Thresholds Scan Results. M3R4-57</b></i></font>

PLOTS of Thresholds Scan Results. M3R4-57

Scan results for FEB-1 (left plots), for FEB-2 (middle plots), for FEB-3 (right plots).
Thr_Max vs channel number (upper plot)
N_Max vs channel number (middle plot)
D_100 vs channel number (lower plot)

For comments, contact: Petr.Neustroev@cern.ch