<i>Thresholds Scan<br />185 M3R4 chambers passed the tests</i></font>

Thresholds Scan
185 M3R4 chambers passed the tests


Tables below present:
- Thr_Max(r.u.), Thresholds in register units at Maximum of noise rate;
- N_Max, Noise rate at Thr_Max in counts/sec;
- D_100 = Thr_100(r.u.) - Thr_Max(r.u.) where Thr_100(r.u.) is the threshold in register units at noise rate = 100/s.
The following expression relates the real threshold (measured from the base-line of physical signals) with the thresholds determined by the register units:
Thr(fC)*S(r.u./fC) = Thr(r.u.) - Thr_Max(r.u.)+ OFFSet(r.u.).
Here, OFFSet=17 register units;
S=3.40 r.u./fC is the charge sensitivity corresponding to S=8mV/fC taken for M3R4 chambers;
(Note, that 1 register unit = 2.35 mV)

FEB-1. Mean values. FEB-2. Mean values. FEB-3. Mean values.
Chamber Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Thr_Max
[r.u.]
N_Max
[counts/s]
D_100
[r.u.]
Test Date Plots Comments
58 82 502072 13 80 508110 12 81 474014 12 18-JUN-07
<font color="DarkRed" size="5"><i><b>Thr_Max in register units for M3R4-58</b></i><br /></font>

Thr_Max in register units for M3R4-58

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 76 85 86 82 82 82 85 80 82 87 86 76 87 78 78 79
FEB-2 69 85 75 78 81 80 87 79 91 79 85 75 85 73 73 80
FEB-3 81 87 86 85 85 92 75 78 77 84 76 85 78 80 78 74
<font color="DarkRed" size="5"><i><b>Noise rate at Thr_Max [counts/sec] for M3R4-58</b></i><br /></font>

Noise rate at Thr_Max [counts/sec] for M3R4-58

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 823564 457288 588890 625277 339319 490130 325692 492061 586831 439099 369997 417276 381968 568177 611877 515702
FEB-2 409332 431163 579409 545633 399315 781475 361823 375805 292245 673394 485022 365906 615275 478038 601244 734688
FEB-3 467484 486154 405728 393912 418012 489468 288919 310745 549911 321951 694370 648100 445522 496553 495826 671576
<font color="DarkRed" size="5"><i><b><FONT FACE="Symbol">D_100 </FONT> - in register units for M3R4-58</b></i><br /></font>

D_100 - in register units for M3R4-58

FEB
Channels
Ch_1 Ch_2 Ch_3 Ch_4 Ch_5 Ch_6 Ch_7 Ch_8 Ch_9 Ch_10 Ch_11 Ch_12 Ch_13 Ch_14 Ch_15 Ch_16
FEB-1 12 13 13 13 13 13 12 12 12 13 12 12 13 12 14 13
FEB-2 12 12 11 11 12 13 11 11 11 13 9 12 14 11 14 11
FEB-3 12 13 10 12 12 12 10 11 11 11 12 13 13 12 13 13
<font color="DarkRed" size="5"><i><b>Noise counts vs Thresholds. M3R4-58</b></i></font>

Noise counts vs Thresholds. M3R4-58


Noise rates vs Thresholds for FEB-1 Noise rates vs Thresholds for FEB-2 Noise rates vs Thresholds for FEB-3
<font color="DarkRed" size="5"><i><b>PLOTS of Thresholds Scan Results. M3R4-58</b></i></font>

PLOTS of Thresholds Scan Results. M3R4-58

Scan results for FEB-1 (left plots), for FEB-2 (middle plots), for FEB-3 (right plots).
Thr_Max vs channel number (upper plot)
N_Max vs channel number (middle plot)
D_100 vs channel number (lower plot)

For comments, contact: Petr.Neustroev@cern.ch